6 - 5
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONINGCONTROL
Device
Device
name
Axis 1 Axis 2 Axis 3
Application
Details when ON
X35
Acceleration/deceleration time change
disable command
Commanding acceleration/deceleration
time change disable
X36
Torque change command
Commanding torque change
X37
Step operation command
Commanding step operation
X38 Skip
command
Commanding
skip
X39
Teaching command
Commanding teaching
X3A
Continuous operation interrupt command
Commanding continuous operation
interrupt
X3B
–
Restart command
Commanding restart
X3C
Parameter initialization command
Commanding parameter initialization
X3D
Flash ROM write command
Commanding flash ROM write
X3E
Error reset command
Commanding error reset
Command
X3F
–
Stop command
Commanding stop
M0
Zero point return request OFF command
Commanding zero point return request
OFF
M1
Zero point return request OFF command
pulse
Zero point return request OFF
commanded
M2
–
Zero point return request OFF command
storage
Zero point return request OFF command
held
M3
Clock data write command pulse
Clock data write commanded
M4
Clock data write command storage
Clock data write command held
M5
High-speed zero point return command
Requesting high-speed zero point return
M6
High-speed zero point return command
storage
High-speed zero point return command
held
M7
Positioning start command pulse
Positioning start commanded
M8
Positioning start command storage
Positioning start command held
M9
In JOG flag
In JOG flag
M10
Manual pulse generator operation enable
command
Requesting manual pulse generator
operation enable
M11
Manual pulse generator operating flag
Manual pulse generator operating flag
M12
Manual pulse generator operation disable
command
Requesting manual pulse generator
operation disable
M13
Speed change command pulse
Speed change commanded
M14
Speed change command storage
Speed change command held
M15
Override command
Requesting override
M16
Acceleration/deceleration time change
command
Requesting acceleration/deceleration time
change
M17
Torque change command
Requesting torque change
M18
Step operation command pulse
Step operation commanded
M19
Skip operation command pulse
Skip operation commanded
M20
Skip operation command storage
Skip operation command held
M21
Teaching command pulse
Teaching commanded
M22
Teaching command storage
Teaching command held
M23
Continuous operation interrupt command Requesting continuous operation interrupt
M24
Restart command
Requesting restart
Internal
relay
M25
–
Restart command storage
Restart command held
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...