12 - 12
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
(2) Precautions during control
(a) The feed pulses of the backlash compensation amount are not added to the
" Md.29 Current feed value" or " Md.30 Machine feed value".
(b) Always carry out a machine zero point return before starting the control
when using the backlash compensation function (when " Pr.12 Backlash
compensation amount" is set). The backlash in the mechanical system
cannot be correctly compensated if a machine zero point return is not
carried out.
(c) Set the No. of pulses output in one backlash compensation (value in which
the " Pr.12 Backlash compensation amount" is divided by the "movement
amount per pulse") to a value of 255 or lower. A "Setting error" will occur if a
value over 255 is set. (Depending on the connected servo, tracking may not
be possible if a large amount of pulses is output at once.)
Backlash compensation amount
0
≤
Movement amount per pulse
≤
255
(Omit values after the decimal point.)
(3) Setting the backlash compensation function
To use the "backlash compensation function", set the "backlash compensation
amount" in the parameter shown in the following table, and write it to the AD75.
The set details are validated at the rising edge (OFF ON) of the PLC READY
signal (Y1D).
Setting item
Setting
value
Setting details
Factory-set
initial value
Pr.12
Backlash
compensation
amount
Set the backlash compensation amount.
0
* Refer to section "5.2 List of parameters" for setting details.
REMARK
•
Parameters are set for each axis.
•
It is recommended that the parameters be set whenever possible with the AD75
software package. Execution by sequence program uses many sequence
programs and devices. The execution becomes complicated, and the scan times
will increase.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...