14 - 18
MELSEC-A
14 TROUBLESHOOTING
Division of
error
Error
code
Error name
Description
Action at occurrence of error
527
Center point
setting error
Circular interporation with center point
designation applicable to one of the following
•
Start point = Center point
•
End point = Center point
•
The center point address is out of the range
between -2147483648 and 2147483647
At start: Operation does not start.
During operation: Immediate stop
530
Outside address
range
•
The positioning address setting is a negative
value in the speed/position changeover
control mode.
•
The positioning address setting of ABS1 or
ABS2 is out of the range between 0 and
359.99999 [degrees].
532
Simultaneous
start not possible
An error other than this one is developed to a
target axis of simultaneous start.
At start: Operation does not start.
During operation: Stopping according to
sudden stop (stopping group 3) setting
(deceleration and stop/sudden stop) selected in
detail parameter 2
(However, deceleration and stop only during
manual pulse generator operation)
533
Condition data
error
One of the following is applicable when
condition data is referred to for a conditional
start, wait start or JUMP command.
•
The target condition setting is out of the
setting range.
•
The condition operator setting is out of the
setting range.
•
The condition operator is range designation
“1” and parameter 1 is bigger than parameter
2.
534
Special start
command error
The command code of the special start
command is out of the setting range.
Operation is terminated.
536
M code ON
signal ON start
Positioning start is performed when the “M
code ON” signal (XD, XE, XF) is turned ON.
537
PLC READY
OFF start
Positioning start is performed when “PLC
READY” (Y1D) is turned OFF.
538 READY ON start
Positioning start is performed when AD75
READY (X0) is turned ON.
543
Outside start
number range
The “positioning start number” setting is other
than 1 to 600, 7000 to 7010, 8001 to 8050, or
9000 to 9003 at positioning start.
Operation does not start at the start.
Positioning
operation
544
Outside radius
range
•
The arc radius exceeds 536870912.
•
The address of auxiliary point, center point
and end point are outside the scope of
-2147483648 to 2147483647 with circular
interpolation.
At start: Operation does not start.
During operation: Immediate stop
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...