12 - 33
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
12.4.4 Hardware stroke limit function
In the "hardware stroke limit function", limit switches are set at the upper/lower limit of
the physical moveable range, and the control is stopped (by deceleration stop) by the
input of a signal from the limit switch. Damage to the machine can be prevented by
stopping the control before the upper/lower limit of the physical moveable range is
reached.
Hardware stroke limit switches are normally installed inside the stroke limit/stroke end
on the drive unit side, and the control is stopped before the stroke limit/stoke end on
the drive unit side is reached.
The details shown below explain about the "hardware stroke limit function".
(1) Control details
(2) Wiring the hardware stroke limit
(3) Precautions during control
(4) When the hardware stroke limit is not used
(1) Control details
The following drawing shows the operation of the hardware stroke limit function.
Mechanical stopper
Drive unit
AD75
Movement direction
Deceleration stop at
upper limit switch detection
AD75 control moveable range
Lower limit
Upper limit
Start
Upper limit switch
Lower limit switch
Drive unit
stroke limit
Drive unit
stroke limit
Start
Movement direction
Mechanical stopper
Deceleration stop at
lower limit switch detection
Fig. 12.19 Hardware stroke limit function operation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...