10 - 13
MELSEC-A
10 ADVANCED POSITIONING CONTROL
10.3.6 Stop
In a "stop", the control is stopped with the "start block data" set in "4: stop".
The control after the point in which the "stop" is set can be restarted by issuing a
"
Cd.13 Restart command".
Section (2) shows a control example where the "start block data" and "positioning data"
are set as shown in section (1).
(1) Setting examples
(a) Start block data setting example
Axis 1 start
block data
Da.10 Shape
Da.11
Start data No.
Da.12 Special
start command
Da.13
Parameter
1st point
1: Continue
1
0: Normal start
–
2nd point
1: Continue
10
4: Stop
–
3rd point
0: End
50
0: Normal start
–
•
•
(b) Positioning data setting example
Axis 1 position-
ing data No.
Da.1 Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
•
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
•
50
00: Positioning complete
•
(2) Control examples
The following shows the control executed when the "start block data" of the 1st
point of axis 1 is set as shown in section (1) and started.
<1> Execute the axis 1 "positioning data No. 1, 2, and 3" and stop the control.
<2> After executing a "restart", execute the axis 1 "positioning data No. 10, 11,
12, and 50", and stop the control.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...