11 - 11
MELSEC-A
11 MANUAL CONTROL
Start time chart
t
Forward run JOG start signal
Forward
JOG run
BUSY signal
Error detection signal
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
[XA]
[X4]
PLC READY signal
AD75 READY signal
Reverse run JOG start signal
Reverse JOG run
[Y16]
[Y17]
[X0]
[Y1D]
Fig. 11.5 JOG operation start time chart