5 - 63
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
When " Pr.1 Unit setting" is "inch"
Da.2
setting value
Value set with peripheral device
(inch)
Value set with sequence program *
1
(
×
10
-5
inch)
ABS Linear 1
: 01
H
ABS Linear 2
: 04
H
Current value change
: 11
H
◊
Set the address
–21474.83648 to 21474.83647 *
2
[–1342.17728 to 1342.17727] *
3
◊
Set the address
–2147483648 to 2147483647
[–134217728 to 134217727]
INC Linear 1
: 02
H
INC Linear 2
: 05
H
Fixed-dimension feed 1
: 03
H
Fixed-dimension feed 2
: 06
H
◊
Set the movement amount
–21474.83648 to 21474.83647
[–1342.17728 to 1342.17727]
◊
Set the movement amount
–2147483648 to 2147483647
[–134217728 to 134217727]
Forward run speed/position : 0F
H
Reverse run speed/position : 10
H
◊
Set the movement amount
0 to 21474.83647
[0 to 1342.17727]
◊
Set the movement amount
0 to 2147483647
[0 to 134217727]
Forward run Speed control : 0D
H
Reverse run Speed control : 0E
H
JUMP command
: 20
H
(Setting not required)
(Setting not required)
◊
Set the address
–21474.83648 to 21474.83647
◊
Set the address
–2147483648 to 2147483647
ABS Circular interpolation : 07
H
ABS Circular right
: 09
H
ABS Circular left
: 0A
H
* Circular interpolation control is not possible when using the stepping motor mode.
◊
Set the movement amount
–21474.83648 to 21474.83647
◊
Set the movement amount
–2147483648 to 2147483647
INC Circular interpolation : 08
H
INC Circular right
: 0B
H
INC Circular left
: 0C
H
* Circular interpolation control is not possible when using the stepping motor mode.
*
1
Decimal points cannot be used in the sequence program, so input the setting value as an integer.
(The value will be converted into the specified value within the system.)
*
2
Setting range for when " Pr.11 Stepping motor mode selection" is "standard mode".
*
3
The values shown in parentheses are the setting range for when " Pr.11 Stepping motor mode selection" is
"stepping motor mode".
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...