5 - 113
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Setting value
Default value
Axis 1 Axis 2 Axis 3
Set with a decimal.
K
Positioning data No.
Setting value
: Positioning data No.
: Block start designation
: Indirectly specification
: Machine zero point return
: High-speed zero point return
: Current value change
· 1 to 600
· 7000 to 7010
· 8001 to 8050
· 9001
· 9002
· 9003
0 1150
1200
1250
Set with a decimal.
K
1
Error reset request
Setting value
After the axis error reset is completed, "0" is stored by the OS.
(Indicates that the axis error reset is completed.)
Axis 1: Axis error is reset.
(Set by sequence program)
0 1151
1201
1251
Set with a decimal.
K
1
Restart command
Setting value
After restart acceptance is completed, "0" is stored by the OS.
(Indicates that the restart acceptance is completed.)
1: Restarts
(Set by sequence program)
0 1152
1202
1252
Set with a decimal.
K
1
M code OFF request
Setting value
After the M code ON signal turns OFF, "0" is stored by the OS.
(Indicates that the OFF request is completed.)
1: M code ON signal turns OFF
(Set by sequence program)
0 1153
1203
1253
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...