5 - 95
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Reading the monitor value
Default value
Axis 1 Axis 2 Axis 3
Monitoring is carried out with a decimal.
Monitor
value
Warning No.
Refer to section "14.3 List of
warnings" for details on the
warning Nos. (warning codes).
0 808
908
1008
Monitoring is carried out with a decimal.
: Step error occurring
: Step stopped
: In step wait
: Error occurring
: Waiting
: Stopped
: Interpolating
: In JOG operation
: In manual pulse generator operation
: Analyzing
: Special start waiting
: In zero point return
: In position control
: In speed control
: In speed control for speed/position
control
: In position control for speed/position
control
Monitor
value
Axis operation state
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
0 809
909
1009
Monitoring is carried out with a decimal.
R
n
-2
mm/min
-3
inch/min
-3
degree/min
0
pulse/s
Monitor
value
Decimal integer
value
Unit conversion table
Actual
value
Unit conversion
R
×
10
n
)
)
Md.36
Current speed
Md.36
Unit
◊
0 810
910
1010
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...