5 - 93
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Reading the monitor value
Default value
Axis 1 Axis 2 Axis 3
0000
H
800
801
900
901
1000
1001
0000
H
802
803
902
903
1002
1003
Monitoring is carried out with a hexadecimal.
A
B
C
D
A
B
C
D
E
F
G
H
E
R
F
G
H
b15
b12
b4
b0
b8
E
F
G
H
b31
b28
b20
b16
b24
A
B
C
D
Monitor
value
Low-order buffer memory Example) 800
High-order buffer memory Example) 801
Sorting
Decimal integer
value
Converted from
hexadecimal to decimal
-1
mm
-5
inch
-5
degree
0
pulse
n
Unit
n
-2
mm/min
-3
inch/min
-3
degree/min
0
pulse/s
Unit
Unit conversion table
Unit conversion
Actual value
(High-order buffer memory) (Low-order buffer memory)
R
×
10
n
)
Md.29
)
Md.30
Unit conversion table
)
)
Md.31
Current feed value
Md.29
Machine feed value
Md.30
Feedrate
Md.31
◊
◊
◊
0000
H
804
805
904
905
1004
1005
Monitoring is carried out with a decimal.
Monitor
value
M code No.
(0 to 32767)
0 806
906
1006
Monitoring is carried out with a decimal.
Monitor
value
Error
No.
Refer to section "14.2 List of
errors" for details on the error
Nos. (error codes).
0 807
907
1007
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...