5 - 86
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Reading the monitor value
Md.13
Start axis
The No. of the axis for which an
error was detected when starting
is stored.
Monitoring is carried out with a decimal.
Storage value
1: Axis 1
2: Axis 2
3: Axis 3
Monitor
value
[Stored contents] The operation information (restart flag, start origin, operation type) is stored.
•
Restart flag
: Whether the operation restarted after stopping once
•
Start origin
: Where the start signal was input from
•
Operation type : What type of operation was carried out
Md.14
Operation type
[Reading the monitor value] Monitoring is carried out with a hexadecimal.
b15
b12
b8
b4
b0
A
B
C
D
B
a
C
D
D
C
B
A
00
01
10
0
1
a : Binary, B to D: Hexadecimal
Buffer
memory
Monitor value
Start origin
Restart flag
Operation type
Stored contents Storage value
PLC CPU
External signal
Peripheral device
Stored contents Storage value
Restart flag OFF
Restart flag ON
a
0
B
0
C
0
D
1
001
1
F
7
C
0
2
5
8
8060
1
F
7
D
8061
1
F
7
3
8051
1
F
7
4
8052
1
F
7
5
8053
600
Stored contents
Storage value
Remarks
(decimal)
Positioning operation
JOG operation
Manual pulse generator operation
Machine zero point return
High-speed zero point return
~
1
B
5
8
1
B
6
2
7010
Block positioning operation
~
7000
Current value change
Md.15
Start time
(Hour: minute)
The error detection time is stored.
(Software clock data created by
system in AD75.)
Monitoring is carried out with a hexadecimal.
0
b15
b12
0 0 1 0 1 0 1 0 0 1 1 0 0 0 0
b8
b4
b0
5
3
0
1
0 to 2 0 to 3 0 to 5
00 to 23
00 to 59
0 to 9
5
1
3
0
Buffer memory (stored with BCD code)
Monitor value
(hour)
(minute)
Md.16
Start time
(Second:100 ms)
The error detection time is stored.
(Software clock data created by
system in AD75.)
Monitoring is carried out with a hexadecimal.
0
b15
b12
1 0 0 1 0 0 1 0 0 0 0 0 1 1 1
b8
b4
b0
9
0
7
4
0 to 5 0 to 9
0
00 to 59
00 to 09
0 to 9
9
4
0
7
Buffer memory (stored with BCD code)
Monitor value
(second) (100 ms)
[Stored contents] The error judgment results when starting (shown below) are stored.
•
BUSY start warning flag
•
Error flag
•
Error No.
Md.17
Error judgment
[Reading the monitor value] Monitoring is carried out with a hexadecimal.
b15
b12
b8
b4
b0
A
B
C
D
B
a
C
D
D
C
B
A
0
1
0
1
a, B, C and D are converted into a decimal,
which can be confirmed in section "14.2 List of errors".
Buffer
memory
Monitor value
Error flag
BUSY start warning
Error No.
Stored contents Storage value
Stored contents Storage value
Error flag OFF
Error flag ON
BUSY start
warning OFF
BUSY start
warning ON
Error at start history (up
to 16 it
ems can
be stored)
Md.18
Starting history
pointer at error
The pointer No. following the
pointer No. where the latest start
history during errors is stored is
indicated.
Monitoring is carried out with a decimal.
Storage value (Pointer No.)
0 to
15
Monitor
value
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...