5 - 66
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
When " Pr.1 Unit setting" is "pulse"
Da.2
setting value
Value set with peripheral device
(pulse)
Value set with sequence program *
1
(pulse)
ABS Circular interpolation : 07
H
ABS Circular right
: 09
H
ABS Circular left
: 0A
H
◊
Set the address
–2147483648 to 2147483647 *
2
◊
Set the address
–2147483648 to 2147483647
INC Circular interpolation : 08
H
INC Circular right
: 0B
H
INC Circular left
: 0C
H
◊
Set the movement amount
–2147483648 to 2147483647
◊
Set the movement amount
–2147483648 to 2147483647
ABS Linear 1
: 01
H
ABS Linear 2
: 04
H
INC Linear 1
: 02
H
INC Linear 2
: 05
H
Fixed-dimension feed 1
: 03
H
Fixed-dimension feed 2
: 06
H
Forward run Speed control : 0D
H
Reverse run Speed control : 0E
H
Forward run speed/position : 0F
H
Reverse run speed/position : 10
H
JUMP command
: 20
H
Current value change
: 11
H
(Setting not required)
(Setting not required)
*
1
Decimal points cannot be used in the sequence program, so input the setting value as an integer.
(The value will be converted into the specified value within the system.)
*
2
Setting range for when " Pr.11 Stepping motor mode selection" is "standard mode".
(Circular interpolation control cannot be carried out when using the stepping motor.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...