5 - 102
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Md.46 Special start data command
code setting value
•
The "command code" used with special start and indicated by the start data
pointer currently being executed is stored.
Md.47 Special start data command
parameter setting value
The "command parameter" used with special start and indicated by the start data
pointer currently being executed is stored.
The stored value differs according to the value set for
Md.46 .
Md.48 Start positioning data No.
setting value
•
The "positioning data No." indicated by the start data pointer currently being
executed is stored.
Md.49 In speed limit flag
•
If the speed exceeds the "
Pr.7 Speed limit value" due to a speed change or
override, the speed limit functions, and the in speed limit flag turns ON.
•
When the speed drops to less than "
Pr.7 Speed limit value", or when the axis
stops, the in speed limit flag turns OFF.
Md.50 In speed change processing
flag
•
The speed change process flag turns ON when the speed is changed during
positioning control.
•
After the speed change process is completed or when deceleration starts with
the stop signal during the speed change process, the in speed change process
flag turns OFF.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...