12 - 85
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
(1) Control data that requires setting
The following control data must be set to execute the indirectly specification
function. Make this setting using a sequence program.
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3
Cd.11
Positioning start No.
8001
Set "8001" that indicates the control
using the "indirectly specification data".
1150 1200 1250
* For the setting details, refer to section "5.7 List of control data".
(2) Starting conditions
The following conditions must be satisfied to make a start. Also, the required
conditions must be incorporated into the sequence program, and the data must
be disabled from starting if the conditions are not satisfied.
Device
Signal name
Signal state
Axis 1 Axis 2 Axis 3
PLC READY signal
ON
PLC CPU preparation completed
Y1D
AD75 READY signal
OFF
AD75 preparation completed
X0
Axis stop signal
OFF
Axis stop signal is OFF
Y13
Y14
Y1C
Start complete signal
OFF
Start complete signal is OFF
X1
X2
X3
BUSY signal
OFF
BUSY signal is OFF
X4
X5
X6
Error detection signal
OFF
There is no error
XA
XB
XC
Interface
signal
M code ON signal
OFF
M code ON signal is OFF
XD
XE
XF
Drive unit READY signal
ON
Drive unit preparation completed
Stop signal
OFF
Stop signal is OFF
Upper limit (FLS)
ON
Within limit range
External
signal
Lower limit (RLS)
ON
Within limit range
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...