12 - 32
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
(7) Setting when the control unit is "degree"
Current value address
The " Md.29 Current feed value" address is ring addresses between 0 and
359.99999° .
0°
0°
0°
359.99999°
359.99999°
Fig. 12.17 Current value address when the control unit is "degree".
Setting the software stroke limit
The upper limit value/lower limit value of the software stroke limit is a value
between 0 and 359.99999° .
(1) Setting when the software stroke limit is to be validated.
When the software stroke limit is to be validated, set the upper limit value in a
clockwise direction from the lower limit value.
Section A
315º
Set in a clockwise direction
Upper limit
Lower limit
90º
Section B
(a) Set the movement range of section A as follows.
•
Software stroke limit lower limit value ................ 315.00000
°
.
•
Software stroke limit upper limit value................ 90.00000
°
.
(b) Set the movement range of section B as follows.
•
Software stroke limit lower limit value ................ 90.00000
°
.
•
Software stroke limit upper limit value................ 315.00000
°
.
Fig. 12.18 Software stroke limit when the control unit is "degree"
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...