4 - 20
MELSEC-A
4 INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT
(Step 3) Operation monitor 2
1) The axis display LED for each axis will turn ON sequentially at an approx.
0.5 second interval.
One of the following states will appear on the 17-segment LED to indicate
the state of the axis for which the axis display LED is ON.
Confirm that the display matches each axis state.
Axis state
17-segment
LED
Remarks
Idle IDL
•
State when power is turned
ON/operation has ended.
Stopped STOP
•
State when positioning
operation is temporarily
stopped.
In JOG operation
JOG
In manual pulse generator operation
MANP
In zero point return
OPR
In position control
POSI
In speed control
VELO
In speed control for speed/position changeover control
V- P
In position control for speed/position changeover control
V -P
–
Waiting BUSY
•
The execution is waiting due to
the condition designation, etc.
Error occurrence *
E***
•
The error code appears in ***.
Refer to Chapter 14 for details
on the errors.
POINT
* When the PLC READY signal [Y1D] is ON, even if a parameter error occurs,
the error code will not appear on the 17-segment LED.
If the error code is not displayed on the 17-segment LED, check the error code
with the peripheral device or AD75 error code storage buffer memory. ( Md.33
Axis error No., Md.34 Axis warning No.)
2) When the mode switch is pressed, the state will shift to the internal
information 1 monitor state described in (Step 4).
(Step 4) Internal information 1 monitor
1) The AD75 OS type ("S003") will appear on the 17-segment LED for
reference.
2) The axis display LED for each axis will turn OFF.
3) When the mode switch is pressed, the state will shift to the internal
information 2 monitor state described in (Step 5).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...