5 - 18
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
5.2 List of parameters
5.2.1 Basic parameters 1
Setting value, setting range
Setting value buffer
memory address
Item
Value set with peripheral
device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3
0 : mm
0
1 : inch
1
2 : degree
2
Pr.1 Unit setting
3 : pulse
3
3 0
150
300
Pr.2
No. of pulses per
rotation (Ap)
(Unit : pulse)
1 to 65535
1 to 65535
1 to 32767:
Set as a decimal
32768 to 65535:
Convert into hexadecimal
and set
20000 1 151 301
Pr.3
Movement amount per
rotation (Al)
The setting value range differs according to the " Pr.1 Unit
setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
20000 2 152 302
1 : 1-fold
1
10 : 10-fold
10
100 : 100-fold
100
Moveme
nt amount
per pulse
Pr.4
Unit magnification (Am)
1000 : 1000-fold
1000
1 3
153
303
Pr.1 Unit setting
This sets the command unit for positioning control. The unit is selected from mm,
inch, degree, pulse according to the control target. The unit for axis 1, axis 2 and
axis 3 can be set independently.
(Example)
mm, inch....... X, Y table, conveyor. (If the machine has inch specifications, set
with an inch unit.)
degree ........... Rotating body. (360 degree/rotation)
pulse.............. X, Y table, conveyor
* Even if the unit setting is changed, the other parameters and positioning data
values will not change. When changing the unit, check that the parameters and
data are within the setting range.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...