7 - 5
MELSEC-A
7 MEMORY CONFIGURATION AND DATA PROCESS
7.1.2 Buffer memory area configuration
The AD75 buffer memory is configured of the following types of areas.
Buffer memory address
Buffer memory area configuration
Axis 1
Axis 2
Axis 3
Writing
possibility
Basic parameter area
0 to 14
150 to 164
300 to 314
Detailed parameter area
15 to 66
165 to 216
315 to 366
Zero point return basic
parameter area
70 to 78
220 to 228
370 to 378
Parameter area
Zero point return detailed
parameter area
79 to 89
229 to 239
379 to 389
Possible
System monitor area
450 to 799
Monitor data area
Axis monitor area
800 to 899
900 to 999
1000 to 1099
Not possible
System control data area
1100 to 1149
Control data area
Axis control data area
1150 to 1199
1200 to 1249
1250 to 1299
Possible
Positioning data area
(No.1 to 100)
Positioning data area
1300 to 2299
2300 to 3299
3300 to 4299
4300 to 4349
4550 to 4599
4800 to 4849
Start block data area
4350 to 4399
4600 to 4649
4850 to 4899
Condition data area
4400 to 4499
4650 to 4749
4900 to 4999
Positioning start
information area
(No.7000)
Indirectly specification
data area
4500 to 4549
4750 to 4799
5000 to 5049
Possible
PLC CPU memo area
PLC CPU memo area
5050 to 5099
Possible
Block transmission area Block transmission area
5100 to 6109
Possible
* Use of address Nos. skipped above is prohibited. If used, the system may not operate correctly.
(For details of the buffer memory address, refer to Appendix 12.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...