5 - 73
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting value
Setting value buffer
memory address
Item
Value set with peripheral
device
Value set with sequence program
Default
value
Axis 1 Axis 2 Axis 3
0 : End
0
Da.10
Shape
1 : Continue
1
Da.11
Start data No.
Positioning data No.: 1 to 600
(01
H
to 258
H
)
01
H
to
258
H
b15
b0
b3
b7
b11
0 0 0
Start data No.
Shape
0000
H
4300 4550 4800
0 : Normal start
00
H
1 : Condition start
01
H
2 : Wait start
02
H
3 : Simultaneous start
03
H
4 : Stop
04
H
5 : FOR loop
05
H
6 : FOR condition
06
H
Da.12
Special start
command
7 : NEXT start
07
H
Da.13
Parameter
Condition data No.:
1 to 10 (01
H
to 0A
H
)
No. of repetitions:
0 to 255 (00
H
to FF
H
)
00
H
to
FF
H
b15
b11
b7
b0
b3
Special start
command
Parameter
0000
H
4350 4600 4850