11 - 10
MELSEC-A
11 MANUAL CONTROL
11.2.4 Creating start programs for JOG operation
A sequence program must be created to execute a JOG operation. Consider the
"required control data setting", "start conditions", "start time chart", and "device
settings" when creating the program.
The following shows an example when a JOG operation is started for axis 1. (" Cd.19
JOG speed" is set to "20000.00mm/min" in the example shown.)
Required control data setting
The control data shown below must be set to execute a JOG operation. The
setting is carried out with the sequence program.
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3
Cd.19
JOG speed
2000000
Set a value equal to or above the "
Pr.10 Bias
speed at start" and equal to or below the
"
Pr.32 JOG speed limit value".
1160
1161
1210
1211
1260
1261
* Refer to section "5.7 List of control data" for details on the setting details.
Start conditions
The following conditions must be fulfilled when starting. The required conditions
must also be assembled in the sequence program, and the sequence program
must be configured so the operation will not start if the conditions are not fulfilled.
Device
Signal name
Signal state
Axis 1 Axis 2 Axis 3
PLC READY signal
ON PLC CPU preparation completed
Y1D
AD75 READY signal
OFF AD75 preparation completed
X0
Axis stop signal
OFF Axis stop signal is OFF
Y13
Y14
Y1C
Start complete signal
OFF Start complete signal is OFF
X1
X2
X3
BUSY signal
OFF BUSY signal is OFF
X4
X5
X6
Error detection signal
OFF There is no error
XA
XB
XC
Interface
signal
M code ON signal
OFF M code ON signal is OFF
XD
XE
XF
Drive unit READY signal ON Drive unit preparation completed
–
Stop signal
OFF Stop signal is OFF
–
Upper limit (FLS)
ON Within limit range
–
External
signal
Lower limit (RLS)
ON Within limit range
–
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...