12 - 8
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
12.2.2 Zero point shift function
When a machine zero point return is carried out, the zero point is normally established
using the near-point dog, stopper, and zero point signal. However, by using the zero
point shift function, the machine can be moved a designated movement amount from
the position where the zero point signal was detected. A mechanically established zero
point can then be interpreted at that point.
The zero point shift function can be used without relation to " Pr.45 Zero point return
method".
The details shown below explain about the "zero point shift function".
(1) Control details
(2) Setting range for the zero point shift amount
(3) Movement speed during zero point shift
(4) Precautions during control
(5) Setting the zero point shift function
(1) Control details
The following drawing shows the operation of the zero point shift function.
Machine zero point return start
Pr.55 Zero point shift amount
Speed selected by the " Pr. 57
Speed designation during
zero point shift"
Pr.49 Creep speed
Shift operation carried out after
the deviation counter clear and reset.
Pr. 46 Zero point return direction
Near-point dog
Pr. 48 Zero point return speed
Zero point signal
Fig. 12.4 Zero point shift operation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...