6 - 29
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Position control operation timing and process time
M code ON signal
(WITH mode)
Cd. 14 M code OFF request
t1
t2
t3
t4
t5
t2
t6
Cd. 14 M code OFF request
Positioning
start signal
Waiting
Controlling position
Waiting
Zero point return complete flag *
[ Md.40 Status:b4]
BUSY signal
Start complete signal
Output pulse to external source
(PULSE)
Positioning operation
Positioning complete signal *
M code ON signal
(AFTER mode)
Md.35 Axis operation status
[Y10,Y11,Y12]
[X4,X5,X6]
[XD,XE,XF]
[X1,X2,X3]
[XD,XE,XF]
[X7,X8,X9]
Fig. 6.9 Position control operation timing and process time
•
When the positioning start signal turns ON, if all signals marked with an
asterisk (*) are already ON, the signals marked with an asterisk (*) will turn
OFF when the positioning start signal turns ON.
Normal timing time Unit: ms
t1 t2 t3 t4 t5 t6
5 to 15
0 to 3.5
Follows
parameters
•
The t1 timing time could be delayed by the following factors.
1) Presence of FROM/TO command execution during start process
2) Operation state of other axes
3) Presence of intervention from peripheral device during start process
4) Details of positioning data to be started
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for A1SD75P1-S3
Page 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...