11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 59
(4) Battery mounting
Connect the MR-BAT6V1BJ using the MR-BT6VCBL03M junction battery cable as follows.
CN2
CN4
Servo amplifier
Orange: Connector for servo amplifier
Black: Connector for branch cable
Encoder cable
HG series servo motors
MR-BT6VCBL03M
MR-BAT6V1BJ
(5) Transporting a servo motor and machine apart
POINT
Be sure to connect the connector for branch cable connection (black) when
transporting a servo motor and machine apart. When the connector for branch
cable connection (black) is not connected to the MR-BT6VCBL03M junction
battery cable, no alarm will occur. However, the absolute position data will be
erased when you transport a servo motor and machine apart.
When you transport a servo motor and machine apart, disconnect only CN2 and CN4 of the servo
amplifier. When other connectors or cables are disconnected between the servo motor and battery, the
absolute position data will be deleted.
CN2
CN4
Servo amplifier
Orange: Connector for servo amplifier
Black: Connector for branch cable
Encoder cable
MR-BT6VCBL03M
MR-BAT6V1BJ
HG series servo motors
Disconnect only CN2
and CN4.
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...