17. APPLICATION OF FUNCTIONS
17 - 5
17.1.4 How to switch J4 mode/J3 compatibility mode
There are two ways to switch the J4 mode/J3 compatibility mode with the MR-J4W_-_B servo amplifier and
MR-J4-_B_(-RJ) servo amplifier.
(1) Mode selection by the automatic identification of the servo amplifier
J4 mode/J3 compatibility mode is identified automatically depending on the connected controller.
When the controller makes a connection request with SSCNET III/H communication, the mode will be
"J4 mode". For SSCNET communication, it will be "J3 compatibility mode".
For the J3 compatibility mode, standard control, linear servo motor control, or direct drive motor control
will be identified automatically with a motor (encoder) connected to the servo amplifier. For the J4 mode,
the operation mode will be the setting of [Pr. PA01].
J4 mode/J3 compatibility
mode automatic
identification
Controller
connection check
J4 mode
J3 compatibility
mode
Connected encoder
check (automatic
identification)
Standard control
(rotary servo motor)
Direct drive motor
control
Factory setting
Linear servo motor
control
Fully closed
loop control
[Pr. PA01] setting
Standard control
(rotary servo motor)
Direct drive motor
control
Linear servo motor
control
Fully closed
loop control
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...