(b) Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in the
regenerative mode.
Servo amplifier
Inverse
efficiency [%]
Capacitor
charging [J]
Servo
amplifier
Inverse
efficiency [%]
Capacitor
charging [J]
MR-J4-10B(-RJ) 55 9
MR-J4-60B4(-RJ) 85 12
MR-J4-20B(-RJ) 75 9
MR-J4-100B4(-RJ)
85 12
MR-J4-40B(-RJ)
85 11
MR-J4-200B4(-RJ)
85 25
MR-J4-60B(-RJ)
85 11
MR-J4-350B4(-RJ)
85 43
MR-J4-70B(-RJ)
85 18
MR-J4-500B4(-RJ)
90 45
MR-J4-100B(-RJ)
85 18
MR-J4-700B4(-RJ)
90 70
MR-J4-200B(-RJ) 85
36
MR-J4-11KB4(-RJ)
90 120
MR-J4-350B(-RJ) 85
40
MR-J4-15KB4(-RJ)
90 170
MR-J4-500B(-RJ) 90
45
MR-J4-22KB4(-RJ)
90 250
MR-J4-700B(-RJ) 90
70
MR-J4-10B1(-RJ) 55
4
MR-J4-11KB(-RJ) 90
120
MR-J4-20B1(-RJ) 75
4
MR-J4-15KB(-RJ) 90
170
MR-J4-40B1(-RJ) 85
10
MR-J4-22KB(-RJ) 90
250
Inverse efficiency (
η
m
): Efficiency including some efficiencies of the servo motor and servo amplifier
when rated (regenerative) torque is generated at rated speed. Efficiency
varies with the speed and generated torque. Since the characteristics of the
electrolytic capacitor change with time, allow for approximately 10% higher
inverse efficiency.
Capacitor charging (Ec): Energy charged into the electrolytic capacitor in the servo amplifier
Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies
by the inverse efficiency to calculate the energy consumed by the regenerative option.
ER [J] =
η
m
• Es - Ec
Calculate the power consumption of the regenerative option on the basis of single-cycle operation
period tf [s] to select the necessary regenerative option.
PR [W] = ER/tf
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...