17. APPLICATION OF FUNCTIONS
17 - 3
Compatible
( : J4 new, : Equivalent to J3, : Not available)
Function Name
MR-J4
series
MR-J3/MR-J3W series
(Note 8)
J4
mode
J3 compatibility
mode
Auto tuning mode 1
A0
A0
Auto tuning mode 2
A0
A0
Auto tuning
2 gain adjustment mode 1
(interpolation mode)
A0
A0
2 gain adjustment mode 2
A0
Manual
mode
A0
A0
Machine resonance suppression filter
1
A0
A0
Machine resonance suppression filter
2
A0
A0
Filter function
Machine resonance suppression filter
3
A0
B0 (Note 15)
Machine resonance suppression filter
4
A0
B0 (Note 15)
Machine resonance suppression filter
5
A0
B0 (Note 15)
Shaft resonance suppression filter
A0
B0 (Note 15)
Low-pass
filter
A0
A0
Robust disturbance compensation
(Note 10)
A0
Robust
filter
A0
B0 (Note 15)
Standard mode/3 inertia mode
A0
B0 (Note 15)
Vibration suppression
control
Vibration suppression control 1
A0
A0
Vibration suppression control 2
A0
B0 (Note 15)
Command notch filter
A0
A0
Gain
switching
A0
A0
Slight vibration suppression control
A0
A0
Overshoot amount compensation
A0
A0
PI-PID switching control
A0
A0
Feed
forward
A0
A0
Applied control
Torque limit
A0
A0
Master-slave operation function
A8 (Note 5)
Scale measurement function
A8 (Note 3)
Model adaptive control disabled
B4
B4
Lost motion compensation function
B4 (Note 5)
(Note 5, 15)
Super trace control
B4 (Note 5)
One-touch
tuning
A0
B0 (Note 15)
Adjustment function
Adaptive tuning
A0
A0
Vibration suppression control 1 tuning
A0
A0
Vibration suppression control 2 tuning
A0
B0 (Note 15)
Fully closed loop electronic gear
A3
A3
Dual feedback control
A3
A3
Fully closed loop control
Semi closed/fully closed switching
loop control
A3
A3
MR-J3-_S
MR-J3-_B-RJ006
Fully closed loop control error
detection function
A3
A3
Linear compatible
Linear servo control error detection
function
A0
A0
MR-J3-_B-RJ004
MR-J3W-_B
Servo motor series/types setting
function
A0
A0
Magnetic pole detection
Direct current exciting method
magnetic pole detection
A0
A0
MR-J3-_B-RJ004
MR-J3-_B-RJ080W
MR-J3W-_B
Current detection method magnetic
pole detection
(Note 6)
A0
MR-J3-_B-RJ004
MR-J3W-_B
Minute position detection method
magnetic pole detection
A0
A0
MR-J3-_B-RJ004
MR-J3-_B-RJ080W
MR-J3W-_B
Initial magnetic pole detection error
detection function
A0
A0
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...