11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 46
(4) Selection example of wires used for wiring
POINT
Selection conditions of wire size are as follows.
600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
(a) Wire size
1) Between P and P4, and between N and N-
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV and servo amplifier.
Total of servo amplifier capacities [kW]
Wire [mm
2
]
1 or less
2 (AWG 14)
2
3.5 (AWG 12)
5
5.5 (AWG 10)
7
8 (AWG 8)
11
14 (AWG 6)
15
22 (AWG 4)
22
50 (AWG 2)
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV-H and servo amplifier.
Total of servo amplifier capacities [kW]
Wire [mm
2
]
11
8 (AWG 8)
15
8 (AWG 8)
22
14 (AWG 6)
(2) Grounding
For grounding, use the wire of the size equal to or greater than that indicated in the following
table, and make it as short as possible.
Power regeneration common
converter
Grounding wire size
[mm
2
]
FR-CV-7.5K to FR-CV-15K
8 (AWG 8)
FR-CV-22K/FR-CV-30K
22 (AWG 4)
FR-CV-37K/FR-CV-55K
38 (AWG 2)
FR-CV-H22K/FR-CV-H30K
8 (AWG 8)
FR-CV-H37K/FR-CV-H55K
14 (AWG 6)
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...