1. FUNCTIONS AND CONFIGURATION
1 - 15
(2) 400 V class
Model:
MR-J4-_(-RJ)
60B4 100B4 200B4 350B4 500B4 700B4 11KB4 15KB4 22KB4
Output
Rated voltage
3-phase 323 V AC
Rated
current
[A]
1.5 2.8 5.4 8.6 14.0
17.0
32.0 41.0 63.0
Main circuit
power supply
input
Voltage/Frequency
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Rated
current
[A]
1.4 2.5 5.1 7.9 10.8
14.4
23.1 31.8 47.6
Permissible voltage
fluctuation
3-phase 323 V AC to 528 V AC
Permissible frequency
fluctuation
Within
±5%
Power supply capacity
[kVA]
Refer to section 10.2.
Inrush current
[A]
Refer to section 10.5.
Voltage/Frequency
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Rated
current
[A]
0.1
0.2
Control circuit
power supply
input
Permissible voltage
fluctuation
1-phase 323 V AC to 528 V AC
Permissible frequency
fluctuation
Within
±5%
Power
consumption
[W]
30
45
Inrush
current
[A]
Refer to section 10.5.
Interface power
supply
Voltage
24 V DC ± 10%
Current capacity
[A]
0.3 (including CN8 connector signals) (Note 1)
Control method
Sine-wave PWM control, current control method
Dynamic brake
Built-in
External option (Note 6, 8)
SSCNET III/H communication cycle (Note 5)
0.222 ms, 0.444 ms, 0.888 ms
Fully closed loop control
Compatible
Scale measurement function
Compatible (Note 7)
Load-side encoder interface (Note 4)
Mitsubishi Electric high-speed serial communication
Communication function
USB: connection to a personal computer or others (MR Configurator2-compatible)
Encoder output pulses
Compatible (A/B/Z-phase pulse)
Analog monitor
Two channels
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo
motor overheat protection, encoder error protection, regenerative error protection, undervoltage
protection, instantaneous power failure protection, overspeed protection, error excessive protection,
magnetic pole detection protection, and linear servo control fault protection
Functional safety
STO (IEC/EN 61800-5-2)
Safety
performance
Standards certified by CB
(Note 9)
EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL3, EN 61800-5-2
Response performance
8 ms or less (STO input off
→
energy shut off)
Test pulse input (STO)
(Note 2)
Test pulse interval: 1 Hz to 25 Hz
Test pulse off time: Up to 1 ms
Mean time to dangerous
failure (MTTFd)
MTTFd
≥
100 [years] (314a)
Diagnosis converge (DC)
DC = Medium, 97.6 [%]
Average probability of
dangerous failures per hour
(PFH)
PFH = 6.4 × 10
-9
[1/h]
Compliance
with global
standards
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standard
UL 508C
Structure (IP rating)
Natural cooling, open
(IP20)
Force cooling, open
(IP20)
Force cooling, open (IP20) (Note 3)
Close
mounting
Impossible
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...