11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 71
(b) 400 V class
Table 11.2 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
] (Note 1)
1) L1/L2/L3/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 3)
MR-J4-60B4(-RJ)/
MR-J4-100B4(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 4)
2 (AWG 14)
AWG 16 to 14
MR-J4-200B4(-RJ)
MR-J4-350B4(-RJ)
MR-J4-500B4(-RJ)
(Note 2)
2 (AWG 14): b
1.25 (AWG 16): a
2 (AWG 14): c
(Note 4)
2 (AWG 14): b
3.5 (AWG 12): a
MR-J4-700B4(-RJ)
(Note 2)
3.5 (AWG 12): a
5.5 (AWG 10): a
MR-J4-11KB4(-RJ)
(Note 2)
5.5 (AWG 10): d
1.25 (AWG 16): b
2 (AWG 14): b
(Note 4)
2 (AWG 14): f
8 (AWG 8): g
MR-J4-15KB4(-RJ)
(Note 2)
8 (AWG 8): g
3.5 (AWG 12): d
MR-J4-22KB4(-RJ)
(Note 2)
14 (AWG 6): i
3.5 (AWG 12): e
5.5 (AWG 10): e
(Note 5)
8 (AWG 8): h
(Note 6)
14 (AWG 6): i
Note 1. Alphabets in the table indicate crimping tools. For crimp terminals and applicable tools, refer to (2)
in this section.
2. To connect these models to a terminal block, be sure to use the screws that come with the
terminal block.
3. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
4. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
5. This is for connecting to the linear servo motor with natural cooling method.
6. This is for connecting to the linear servo motor with liquid cooling method.
Use wires (5)) of the following sizes with the power regeneration converter (FR-RC-H).
Model Wire
[mm
2
]
FR-RC-H15K
14 (AWG 6)
FR-RC-H30K
FR-RC-H55K
(c) 100 V class
Table 11.3 Wire size selection example (HIV wire)
Servo amplifier
Wires
[mm
2
]
1) L1/L2/
2) L11/L21
3) P+/C
4) U/V/W/
(Note 1)
MR-J4-10B1(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
(Note 2)
2 (AWG 14)
AWG 18 to 14
(Note 2)
MR-J4-20B1(-RJ)
MR-J4-40B1(-RJ)
Note 1. The wire size shows applicable size of the servo amplifier connector and terminal block. For wires
connecting to the servo motor, refer to each servo amplifier instruction manual.
2. Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...