Installation and Maintenance Manual
System Configuration
Installation and Maintenance Manual v4/0615/10
41
Powering up the P308
1
Connect the P308 to the system via the LINK port on the front of the module. This can be either via
the network or directly to a LAN port on a 5100/5018 Call Server or Phone Module.
2
The module will request an IP address from a DHCP server. It will make 4 attempts and then back
off for a period before trying again. The back off period will extend for each failed attempt. The
right LED (yellow) on the LINK port will toggle on/off every 5 seconds while waiting for an IP
Address.
3
Having obtained an IP address (the right LED on the LINK port turns off) the module broadcasts to
find a Call Server to provide its configuration and become active.
4
If the Auto Add Phones feature is turned on the P308 will automatically register with the system
If the Auto Add Phones feature is turned off the P308 must be manually registered as follows:
a
In Manager select Unassigned Modules
b
The P308 will be displayed together with its MAC address
c
Select this link
d
The Module Status field will display Available
e
From the Module Status list box select Member
f
Select Update or Apply when ready
g
This unit will now be listed under Modules
5
The right hand LED of the LINK port will turn on and become solid when the module is ready.
Connect each analogue handset to a port on the P308 module via a master dongle or RJ45 connection if
supplied. For further details on connecting an analogue handset please refer to the Connecting an
Analogue Phone section from page 48.
A P308 controls the:
x
Ringing of the telephones at the requested cadence
x
Presentation of the CLI
x
Recognition of off-hook state
x
Recognition of dialled DTMF tones
x
Presentation of DTMF for fax servers
Configuring a P308
1
In Manager select Modules
2
The P308 will be displayed together with its MAC address, indicated by “Phone 308” in the Type
column.
3
Select this link to view and configure this module.
Name, Description and Location
–
these are text fields and can be used to help identity the P308.
The Name must be unique, should consist of alphanumerical characters only, not contain any
punctuation and begin with a letter.
Serial Number
–
hardware address of the module.
IP Address
–
displays the IP address being used by the P308. On initial installation this will be
provided via DHCP, however if static IP address is required this can be configured manually via the
module’s
network configuration pages as described below.
Product Version - will display which version of software is currently running on the P308. For
information on upgrading this software please refer to page 288.
Module Status
–
should be set to Member as configured during set up.