Installation and Maintenance Manual
Configuring system functionality
188
Installation and Maintenance Manual v4/0615/10
29
Select Update
30
Select Update or Apply when ready.
31
Connect the relevant dongle to the relevant port and connect this to the device requiring ISDN
Please note:
x
No call progress tones are provided
x
When setting up Trunk ports to simulating ISDN into your system in a test environment the call can
go out on any port other than the NT port.
Trunk NT Mode Dongles
For technical data on NT mode dongles please refer to the maximiser Technical Reference manual.
Configuring DPNSS
A PRI port provided by a Call Server or Trunk Module can be configured to support DPNSS. No additional
licence is required for this feature other than a Trunk licence to enable a channel on the PRI port. This
implementation of DPNSS will support: Simple Calls, Name, Number, Loop Avoidance, Data Call, and
Node Numbers including Message Waiting and Visual Voice for Index.
Please refer to SpliceCom Support for assistance with configuration of DPNSS.
Creating a H.323 trunk
A Call Server can support H.323 Trunk services and can be configured as follows. Please note that the
required number of Trunk licences (one per channel) must be entered to use this facility (please refer to
page 20 for further details). When using a 4100 Call Server or 4140 Remote Call Server a Voice
Compression Module or card is required to use this facility across the Internet (please refer to page 36 for
further details).
1
In Manager select Modules
2
From the Module list select the Add H323 Gateway button
3
In the Name field enter a name to identify this external gateway
4
Enter the IP address of the remote end.
5
Select Apply