Installation and Maintenance Manual
Field Descriptions
Installation and Maintenance Manual v4/0615/10
337
Trunk
List of Trunks (GUIDs) that are members of the Trunk Group
DDI Plans
Name
64 Domain Characters (GUID). Name of the DDI Plan
Description
128 Characters. Text description of this DDI Plan
DDI Entries
Order
Determines the position of an entry within a DDI Plan. DDI Plan entries are read from top to bottom by
the system. Entries will be listed in sequential order with low numbers at the top and higher numbers
lower down.
Description
128 characters. Text field to enter a description for this entry.
Time Plan
The name (GUID) of the Time Plan to determine when this entry is active.
Number Match
64 Characters. The incoming DDI number to be matched. An exact match is required. This number will
also be the outgoing CLI for the extension number entered in the Translate To field.
Bearer Capability
Set to Voice, Data, Video or Fax. Informational field only.
Caller ID
64 Characters. The number to be matched against incoming CLI. Left hand matching.
Translate To
64 Characters. The number or name to which the incoming call is to be routed. This can be a User,
Contact, Department, or external number. If a DDI Call Plan entry is to be used to determine the
outgoing CLI for a call enter the User or Department’s extension number in this field.
Locale
Not used
LCR Plans
Name
64 Domain Characters (GUID). Name of the LCR Plan.
Description
128 Characters. Text description of this LCR Plan