Each port is provided with two LEDs to display the following activity on the port:
Left hand LED = displays when phone ringing
Right hand LED = displays when phone in use
When a 5100 or 4140 Call Server or Phone Module is rebooted each analogue handset will ring once to
confirm communication with the system and will display the number of new voicemail messages waiting
for the User assigned to that phone (if voicemail enabled).
Calls placed on hold will be automatically taken off hold after 10 minutes.
Analogue Ports on a 5100 Call Server
The first eight analogue ports on the 5100 Call Server are activated on installation. However ports 9-16
require a POTS licence to enable each port. Once the required number of POTS licences have been
installed as described in the Installing Licences section from page 20 the following configuration is
required:
1
In Manager select Phones
2
Select the relevant 5100 Call Server
3
Select the relevant analogue port
–
port09-port16
4
Remove the tick from the Unlicensed Port field
5
Select Update or Apply when ready.
For further information on configuring an analogue port please refer to page 89.
Each User assigned to ports 9-16 will also require the following configuration:
1
In Manager select Phones
2
Select the relevant 5100 Call Server
3
Select the relevant analogue port
–
port09-port16
4
Select the entry displayed in the User field eg Extn2009
5
The User configuration form will be displayed
6
Remove the tick from the Ex Directory field (unless required)
7
Select Apply
8
Select the Licences page
9
Remove the tick from the Disable (lack of licence) field
10
Select Update or Apply when ready.
For further information on User configuration please refer to the Working with Users section from
page 94.
Increasing the volume on an analogue port
5300 Phone Module
Setnet can be used to increase the volume given out on each analogue port on a Phone Module as
follows:
1
Within the Command prompt enter
telnet <ip address of Phone Module>
eg telnet 192.168.0.250
then press Enter
2
You will be prompted for a Username, enter
diag
, then press Enter