Installation and Maintenance Manual
System Configuration
50
Installation and Maintenance Manual v4/0615/10
3
You will be prompted for the password for this Phone Module. By default this is
7388
. (The
Password is set within th
e relevant Phone Module’s configuration form.) Then press Enter.
4
Wait for a hash (#) to appear to confirm a connection has been made to the Phone Module
5
Enter
setnet
then press Enter
6
The current configuration will be displayed. You will be asked if you wish to change any of this
configuration.
7
Enter
y
then press Enter
8
Press Enter until the line “Audio Level” appears
9
Type in either
6
(recommended) or
12
depending on the volume level required.
10
Press Enter
11
You will be prompted to save this new configuration. Enter
y
.
12
The configuration will be saved.
13
Enter
poweroff
to reboot the phone module.
5100/5108 Call Server
To increase the volume output for the analogue ports on a Call Server a file called pots_level must be
created within the /SpliceCom directory as follows:
1
Telnet on to the Call Server as described in the Root Access to a Call Server section from page 272
2
Enter
vi /SpliceCom/pots_level
3
Press
i
to go to Insert mode
4
Type in either
6
(recommended) or
12
5
Press Esc to exit Insert mode
6
Enter
:wq
to quit the file and save the changes.
7
Reboot the Call Server
Connecting a PCS 520
When connecting a PCS 520 to an analogue port the following should be considered:
Caller Display Type
The Default Caller Display Type for an analogue port will be suitable for use with the PCS 520 however to
ensure that CLI information is displayed correctly and to allow the handset is to support Paging and Auto
Answer the System Phone Caller Display Type should be used. For details on how to configure an
Analogue Extension port please refer to page 89.