Installation and Maintenance Manual
System Configuration
Installation and Maintenance Manual v4/0615/10
29
The additional Users, up to 12, can now be created assuming the required number of IPUser licences
have been installed.
Connecting a Module
Connecting an Intelligent Gateway Module PSU (PoE4)
The PoE4 provides four Power over Ethernet ports, primarily for use with the Intelligent Gateway Modules.
Please refer to the Technical Reference manual for technical data relating to this module.
1
Connect the PoE4 to the system via the LINK port on the front of the module. This can be either via
the network or directly to a LAN port on a 5100/5018 Call Server or Phone Module.
1
Power up the unit.
Connecting an ISDN Trunk Gateway
A Basic Rate ISDN Trunk Gateway (I208) and a Primary Rate ISDN Trunk Gateway (I230) can be connected
to a system to provide ISDN connectivity for S8000/S716 Call Server systems or for increasing the number
of ISDN ports available on a system containing 5100/5108/NSG modules.