VOL.3-354
CHAPTER 2
TERMINAL-RELATED DEVICES
8.7.2
Light Level Check
Using a Fiber Optic Power Meter, make sure that the light level at points [1] through [4] is within the range of “Nor-
mal Light Level” indicated by the table below. If it is not, perform the following repair procedure.
Light Level Check Points and Repair Procedure
Note:
For MMF, be sure to use 62.5/125
μ
m or 50/125
μ
m. However, 62.5/125
μ
m and 50/125
μ
m cannot coexist
in a system.
Normal Light Level
MAXIMUM DISTANCE BETWEEN
PBX and DCS
POWER LEVEL
(SEND)
POWER LEVEL
(RECEIVE)
MMF
Note
2 km
–20 ~ –14 dBm
–27 ~ –14 dBm
SMF
15 km
–15 ~ –8 dBm
–27 ~ –8 dBm
RX
TX
Telephony Server
DCS0
DCS1
TX
RX
TX
RX
OPTMUX
ROPTMUX
Outbound
Inbound
PA-CC109
PA-CC110
PA-CC111
PA-CC112
Error at Check Point [1]
Replace OPTMUX.
Error at Check Point [3]
Replace ROPTMUX.
Error at Check Point [4]
Check Inbound Cable.
Error at Check Point [2]
Check Outbound Cable.
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
Fiber Optic Power Meter
If light level of any check point is out of range, perform the corresponding repair procedure.
Содержание SV8500
Страница 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Страница 67: ...VOL 1 7 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK 2 Select Scope Create on the menu bar as shown below ...
Страница 103: ...VOL 1 43 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK STEP 8 Highlight Scope 10 0 0 0 ss2 and select Action Activate ...
Страница 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Страница 122: ...VOL 1 62 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK STEP 3 Click Finish to complete the DNS installation ...
Страница 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Страница 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Страница 1596: ...VOL 2 1343 MG SIP128 MG 128SIPMGG Port Settings tab opens Set the values as the following figure shows ...
Страница 1723: ...VOL 2 1470 MG SIP128 MG 128SIPMGJ Port Settings tab opens Set the values as the following figure shows ...
Страница 1734: ...VOL 2 1481 MG SIP128 MG 128SIPMGJ 18 4 Operation and Maintenance Here explains MG SIP128 MG 128SIPMGJ operation and maintenance ...
Страница 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Страница 1864: ...VOL 2 1611 MG SIP96 19 4 Operation and Maintenance Here explains MG SIP96 operation and maintenance ...
Страница 2336: ...VOL 2 2083 SR MGC E 25 SR MGC E Here explains an SR MGC E function overview configuration installation procedure ...
Страница 2613: ...VOL 3 126 CHAPTER 2 TERMINAL RELATED DEVICES SN886 DRE B SW70 SW71 PWR LB ALM LINK IVDCN BATT0 BATT1 LED PZ 23ELCN CHAMP0 CHAMP1 ...
Страница 2638: ...VOL 3 151 CHAPTER 2 TERMINAL RELATED DEVICES Fastening of STAND ASSEM STAND ASSEM Set Screw Set Screw ...
Страница 2640: ...VOL 3 153 CHAPTER 2 TERMINAL RELATED DEVICES Installation of DRU DAU Wall Mounting DRU DAU Wood screw Wood screw ...
Страница 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Страница 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Страница 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Страница 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Страница 3116: ...VOL 3 629 CHAPTER 4 CONFIGURATION SETUP g Others EMEA Bg Upper case h Others EMEA Sm Lower case ...
Страница 3117: ...VOL 3 630 CHAPTER 4 CONFIGURATION SETUP FW 2 2 X X or earlier except for DT730G a English Bg Upper case ...
Страница 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Страница 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Страница 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Страница 3121: ...VOL 3 634 CHAPTER 4 CONFIGURATION SETUP g Others EMEA Bg Upper case h Others EMEA Sm Lower case ...
Страница 3414: ...VOL 3 927 CHAPTER 4 CONFIGURATION SETUP 8 The Telephony Server normally starts up the IP station ...
Страница 3438: ...Printed in Japan 1307 120 ...