VOL.2-2182
SR-MGC
<Office Data Copy Tab>
Select either of the radio buttons, Specifying SR-MGC or All SR-MGC (en bloc specifying) on the Man-
ual Copy tab to execute office data copy manually.
•
Specifying SR-MGC
Click the Execute button after specifying the target SR-MGC number (0 ~ 255).
•
All SR-MGC (en bloc specifying)
Click the Execute button to execute office data copy to all the SR-MGCs in the network.
Note:
Do not perform any PCPro operations other than CMNT command during office data copy. The PCPro
operation such as login/logoff can cause a copy failure.
Note 1:
When the Break button is pressed during office data copy, the operation is cut off after the currently
copying file is completely copied. However, when DM/LDM/NDM copy is executed, the operation is
cut off after all the DM/LDM/NDM files are copied.
File copy operation takes about two minutes per file. (The time varies depending on the connection sta-
tus of the network.)
Note 2:
If you power off the SR-MGC during the office data copy, check the data as follows:
STEP1: Use CMNT command to check the normality of communication between SR-MGC and the Te-
lephony Server (MGC).
STEP2: If the status of the communication is normal, copy the Office Data into SR-MGC. If the com-
munication is not established, set network settings of SR-MGC, and then copy the Office Data into SR-
MGC.
When none of the above is performed at the situation, it is not guaranteed that SR-MGC operates nor-
mally.
[5] Initialize SR-MGC
After finishing office data copy, the Telephony Server (MGC) requests the SR-MGC to initialize. Wait for
the SR-MGC to be initialized, which takes about five minutes.
<About SR-MGC initialization>
If the Office Data Copy is performed in the following status, initialization of SR-MGC (initialize the SR-
MGC by the CMNT command or power off and on the SR-MGC again) is required.
•
When there is no office data file on the Flash card of SR-MGC
•
After the change of the office data requiring Telephony Server (MGC) initialization
(a) Initialize the SR T using the “Initial” tab of the
CMNT
command. Select the radio button “Individual
Initial” and enter the SR-MGC Number of the target SR-MGC.
SR-MGC
Telephony Server
PCPro
Office Data
Содержание SV8500
Страница 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Страница 67: ...VOL 1 7 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK 2 Select Scope Create on the menu bar as shown below ...
Страница 103: ...VOL 1 43 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK STEP 8 Highlight Scope 10 0 0 0 ss2 and select Action Activate ...
Страница 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Страница 122: ...VOL 1 62 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK STEP 3 Click Finish to complete the DNS installation ...
Страница 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Страница 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Страница 1596: ...VOL 2 1343 MG SIP128 MG 128SIPMGG Port Settings tab opens Set the values as the following figure shows ...
Страница 1723: ...VOL 2 1470 MG SIP128 MG 128SIPMGJ Port Settings tab opens Set the values as the following figure shows ...
Страница 1734: ...VOL 2 1481 MG SIP128 MG 128SIPMGJ 18 4 Operation and Maintenance Here explains MG SIP128 MG 128SIPMGJ operation and maintenance ...
Страница 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Страница 1864: ...VOL 2 1611 MG SIP96 19 4 Operation and Maintenance Here explains MG SIP96 operation and maintenance ...
Страница 2336: ...VOL 2 2083 SR MGC E 25 SR MGC E Here explains an SR MGC E function overview configuration installation procedure ...
Страница 2613: ...VOL 3 126 CHAPTER 2 TERMINAL RELATED DEVICES SN886 DRE B SW70 SW71 PWR LB ALM LINK IVDCN BATT0 BATT1 LED PZ 23ELCN CHAMP0 CHAMP1 ...
Страница 2638: ...VOL 3 151 CHAPTER 2 TERMINAL RELATED DEVICES Fastening of STAND ASSEM STAND ASSEM Set Screw Set Screw ...
Страница 2640: ...VOL 3 153 CHAPTER 2 TERMINAL RELATED DEVICES Installation of DRU DAU Wall Mounting DRU DAU Wood screw Wood screw ...
Страница 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Страница 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Страница 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Страница 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Страница 3116: ...VOL 3 629 CHAPTER 4 CONFIGURATION SETUP g Others EMEA Bg Upper case h Others EMEA Sm Lower case ...
Страница 3117: ...VOL 3 630 CHAPTER 4 CONFIGURATION SETUP FW 2 2 X X or earlier except for DT730G a English Bg Upper case ...
Страница 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Страница 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Страница 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Страница 3121: ...VOL 3 634 CHAPTER 4 CONFIGURATION SETUP g Others EMEA Bg Upper case h Others EMEA Sm Lower case ...
Страница 3414: ...VOL 3 927 CHAPTER 4 CONFIGURATION SETUP 8 The Telephony Server normally starts up the IP station ...
Страница 3438: ...Printed in Japan 1307 120 ...