Operator's Manual
WP700Zi-OM-E-RevA
170
Setting Up Parameter Math
1. Touch
Measure Measure Setup
on the menu bar.
2. Touch
the
My Measure
button in the
Measure
dialog.
3. Touch
the
Px
tab for the parameter to which you want to apply parameter math.
4. In
the
Px
dialog, touch the math on parameters button
. The
Source
field expands to two fields.
5. Touch
inside
the
Source1
and
Source2
fields and select the parameters you want to apply math to (P1 to
Px). If you are applying math to a single parameter (for example, invert), just touch inside the
Source1
field
and select a parameter (P1 to Px).
6. Touch
inside
the
Math Operator
field and select a math operation from the
Select Measurement
menu. If
you select an operation that requires two input parameters, the
Source
field will expand to two fields.
Setting Up Parameter Script Math
1. Touch
Measure
Measure Setup
on the menu bar.
2. Touch
the
My Measure
button in the
Measure
dialog.
3. Touch
the
Px
tab for the parameter to which you want to apply parameter math.
4. In
the
Px
dialog, touch the math on parameters button
. The
Source
field expands to two fields.
5. Touch
inside
the
Source1
and
Source2
fields and select the parameters you want to apply math to (P1 to
Px). If you are applying math to a single parameter (for example, invert), just touch inside the
Source1
field
and select a parameter (P1 to Px).
6. Touch
inside
the
Math Operator
field and select P Script
from the
Select Measurement
menu.
7. In
the
Script Math
dialog, touch inside the Script Language field and select either
VBScript
or
JScript
from the pop-up menu.
8. Touch
the
Edit Code
button. The
Script Editor
window opens. You can enter code in this window or call
up an existing script from a file storage location. If you create your script in this window, you can then
export it and save it to file.
Measure Gate
Using Measure Gate, you can narrow the span of the waveform on which to perform parameter measurements,
allowing you to focus on the area of greatest interest. You have the option of dragging the gate posts horizontally
along the waveform, or specifying a position down to hundredths of a division. The default starting positions of the
gate posts are 0 div and 10 div, which coincide with the left and right ends of the grid. The gate, therefore, initially
encloses the entire waveform.
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...