WavePro 7Zi
499
WP700Zi-OM-E-RevA
keyword:
KEYWORDS_VERSION
arguments:
1
required?:
yes
possible error
messages:
"Keywords version is newer than software rev!" When the keywords file is updated, this
message will specify KEYWORDS_VERSION 2. New software will be able to handle
versions 1 and 2. Old software will produce this error message if it encounters
KEYWORDS_VERSION 2.
keyword:
LEVELS
arguments:
<number from 3 to 32>
required?:
yes
Note:
LEVELS must appear before NORMALIZED_LEVELS are specified
possible error messages:
"#levels must be >= 3 and <= 32!"
keyword:
MAX_LEVEL_ADJ
arguments:
<value from 0.0 to 1.0>
required?:
no
Notes:
This sets a hard limit on the maximum change in an expected level due to steering from
one sample. Setting this value to 1.0, or near that value, makes the limit irrelevant. The
DDA uses 0.0625 for PR4, 0.03125 for EPR4, and 0.020833 for E2PR4. If this keyword is
not seen, its value remains unchanged. If this value is never set, the default is 0.020833.
possible error
messages:
"MAX_LEVEL_ADJ must be >= 0 and <= 1.0"
keyword:
MAX_PHASE_ADJ
arguments:
<value 0 to 0.1>
required?:
no
Notes:
This sets a hard limit on the maximum phase change (and the maximum period change) of
the emulated PLL due to steering from one sample. The value is a fraction of a bit cell time.
The DDA uses 0.06 for PR4 and EPR4, and 0.04 for E2PR4. If this keyword is not seen, its
value remains unchanged. If this value is never set, the default is 0.04.
possible error
messages:
"MAX_PHASE_ADJ must be >=0 and <=0.1 (bit cells)"
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...