Parameter
Description
Definition
Notes
frequency of a waveform
(narrow band).
Standard in DDA-5005A and
SDA100G scopes.
N-cycle Jitter
Peak-to-peak jitter between
edges spaced
n
UI apart.
Compares the expected
time to the actual time of
leading edges n bits
apart.
Available in SDA analyzers.
NLTS
Provides a measurement of
the nonlinear transition shift
for a prml signal.
Available with DDM2 option.
Standard in DDA-5005AA.
None
Disable parameter
calculation
Standard parameter.
Num Points
(npoints)
Number of points in the
waveform between the
cursors.
Standard parameter.
One Level
(one)
One level of an eye diagram
Available with SDA and SDM
options.
Standard in SDA, SDA100G, and
WaveExpert scopes.
Overshoot-
Overshoot negative: Amount
of overshoot following a
falling edge, as percentage
of amplitude.
(base - min.)/ampl x 100
Waveform must contain at least one
falling edge. On signals not having
two major levels (triangle or saw-
tooth waves, for example), may not
give predictable results.
Standard parameter.
Ov
Overshoot positive: Amount
of overshoot following a
rising edge specified as
percentage of amplitude.
(max. - top)/ampl x 100
Waveform must contain at least one
rising edge. On signals not having
two major levels (triangle or saw-
tooth waves, for example), may not
give predictable results.
Standard parameter.
Overwrite
(owrite)
Ratio of residual-to-original
power of a low frequency
waveform overwritten by a
higher frequency.
Available with DDM2 option.
Standard in DDA-5005A.
Param Script
(script)
Visual Basic or Java script
that produces a
measurement from one or
two input waveforms.
Available with XMAP, XDEV, and
ASDA options.
Standard in DDA-5005A.
Pattern Time
(Ptime)
Detects a bit pattern in a
digital sequence and outputs
the start and stop time of the
pattern.
Available with SDA and PCIE
options.
Standard in SDA100G scope.
Peak Mag
(pkmag)
Peak mag away from a
baseline. Note: the measure
gate must include more of
the baseline than any other
single level.
Available with ENET option.
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...