WavePro 7Zi
321
WP700Zi-OM-E-RevA
Using time cursors, it can be seen that the beginning of this problematic
pit width occurred at pit # 973, 859.61
P
s from the trigger. This smaller-
than-normal pit is 245.40 ns.
Now that a problem has been identified, we would like to view the portion of the waveform in which the problem
occurred. Change the display mode Single grid. Turn off the two trend traces, leaving only F3, which is the
expanded trace of Channel 1. Move the absolute time cursor to the position in the trace at 859
P
s; and, using the
WAVEPILOT position controls, position the waveform so that the cursor on the trace is at the center of the screen.
Expand the waveform using the horizontal zoom control.
Here is the waveform zoomed in a bit with the measurement
cursor placed at 859.600
P
s. As can be seen, there is some kind
of aberration at the center of the trace.
Further zooming clearly identifies the problem: a burst error that
prevented the positive polarity width that starts at 859.61
P
s from
reaching its peak value. This defect caused the reflectivity to drop
and to erratically fluctuate throughout the duration of the burst
error. The defect affected the width of the next pit as well, which
created the pit width centered between the 4T and 5T band of the
XY plot.
TIMJ - TIMING JITTER
Description
Timing Jitter provides a measurement of the standard deviation of the difference of the width of pits and/or spaces
from the mean width. The width of the pit/space is determined by the crossing of the selected voltage threshold.
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...