WavePro 7Zi
193
WP700Zi-OM-E-RevA
Parameter
Description
Definition
Notes
rectangular waveforms and
represents the higher most
probable state determined
from the statistical
distribution of data point
values in the waveform.
histograms, result may include
contributions from more than one
acquisition.
Standard parameter.
Total Jitter
(Tj)
Total jitter at a user-specified
bit error ratio.
Available with ENET and SDA
options.
Total Pop
(totp)
Total population of a
histogram.
Available with DDM2, JTA2,
XMATH, XWAV, CAN02, SDA, and
XMAP options.
Standard in DDA-5005A, SDA100G,
WaveExpert, and sampling scopes
tUpS
Upsamples a time parameter
by a user-specified factor.
Available with SDA and SDM
options.
TxCmD
PCI Express: V TX-CM-DC-
LINE-DELTA
Absolute delta of DC
common mode voltage
between D+ and D-
Available with PCIE option.
TxFall
Transition time from 80% to
20% for all falling edges as a
fraction of UI.
Available with PCIE option.
TxRise
Transition time from 20% to
80% for all rising edges as a
fraction of UI.
Available with PCIE option.
Vcross
Voltage at which two signals
cross.
Voltage of either signal at
the time when difference
is zero.
Available with SDA and PCIE
options.
Vdiff
Used for V TX-DIFFp-p and
V RX-DIFFp-p for PCI-
Express.
Available with PCIE option.
VTxDeRatio
Ratio between transition and
de-emphasized bits.
Available with PCIE option.
Width
Width of cyclic signal
determined by examining
50% crossings in data input.
If first transition after left
cursor is a rising edge,
waveform is considered to
consist of positive pulses and
width the time between
adjacent rising and falling
edges. Conversely, if falling
edge, pulses are considered
negative and width the time
between adjacent falling and
rising edges. For both cases,
widths of all waveform pulses
are averaged for the final
Width of first positive or
negative pulse averaged
for all similar pulses
Similar to fwhm, though, unlike
width, that parameter applies only to
histograms.
Standard parameter.
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...