WavePro 7Zi
45
WP700Zi-OM-E-RevA
x
Quick Zoom
- Press to automatically display magnified views of up to four signal inputs on multiple grids.
With four input signals, the signals are displayed along with four zoom traces, each on its own grid.
Pressing this button also turns off all other traces.
x
Vertical Position
- Press to reset the vertical zoom position to zero. Turn to change the vertical position of
the selected math or zoom trace.
x
Vertical Ratio
- Press to toggle between fixed and variable vertical zoom ratio adjustment. Turn to change
the vertical zoom ratio of the selected math trace.
Screen Layout, Groupings, and Controls
The instrument's screen is divided into three main sections:
x
Menu
Bar
x
Signal Display Grid
x
Dialog(s)
Note
: Some front panel controls correspond with screen layout controls in specific ways. For example, the
front panel general control button corresponds with the
Hardcopy
function at
Utilities Utilities Setup
Hardcopy
.
Menu Bar
The top of the screen contains a menu bar of commonly used functions. Whenever you touch one of these
buttons and make a selection from its drop-down menu, the dialog area at the bottom of the screen displays the
corresponding dialog.
Specific Menu Bar functions are referenced using arrow-separated path descriptions. For example, the
Save Setup
function is referenced as
File Save Setup
.
The Quick Access Toolbar
The Quick Access toolbar is located on the right side of the menu bar. You can use these toolbar buttons to
quickly access trigger functions.
x
Auto
- Press to turn on
Auto Trigger
mode, which triggers the oscilloscope after a time-out, even if the
trigger conditions are not met.
x
Normal
- Press to turn on
Normal Trigger
mode, which triggers the oscilloscope each time a signal is
present that meets the conditions set for the type of trigger selected.
x
Single
- Press to turn on
Single Trigger
mode for the selected channel, which arms the oscilloscope to
trigger once (single-shot acquisition) when the input signal meets the trigger conditions set for the type of
trigger selected. If the scope is already armed, it will force a trigger.
x
Stop
- Press to prevent the scope from triggering on a signal. If you boot up the instrument with the trigger
in
Stop
mode, the message "no trace available" will be displayed.
x
Trigger Setup
- Press to open the
Trigger Setup
dialog. Corresponds with screen menu selection:
Trigger Trigger Setup
.
The Signal Display Grid
You can set up the signal display area by touching
Display
Display Setup
from the menu bar. The
Display
dialog offers a choice of grid combinations and can also set the grid intensity.
The following Display Grid features also provide assistance when using the oscilloscope:
x
Descriptor Labels
- For more information, go to the
Trace Descriptors
topic.
Содержание DDA 7 Zi series
Страница 1: ...Operator s Manual WavePro SDA and DDA 7 Zi Series Oscilloscopes ...
Страница 2: ... L R R H HUD RU D D ...
Страница 41: ...Operator s Manual WP700Zi OM E RevA 40 The detachable WavePro Zi front panel ...
Страница 376: ...WavePro 7Zi 375 WP700Zi OM E RevA Absolute Offset Relative ...
Страница 439: ...Operator s Manual WP700Zi OM E RevA 438 ...
Страница 440: ...WavePro 7Zi 439 WP700Zi OM E RevA ...
Страница 544: ...Thank you for purchasing a WavePro SDA or DDA 7 Zi Oscilloscope ...