When MLPPP reassembly is disabled, this restriction is not in effect; for
example, member links can span paths in different bundles.
■
Any combination of bundles that does not exceed the 336 available T1
channels (for example, 336 single-link T1 bundles, 42 eight-link bundles, or
41 eight-link bundles and 8 single-link bundles)
■
Any combination of bundles that does not exceed the 252 available E1
channels (for example, 252 single-link T1 bundles, 34 eight-link bundles, or
33 eight-link bundles and 8 single-link bundles)
■
On a CT3/T3-F0 line module with a CT3/T3 12 I/O module, you can configure:
■
Member links from different T3 ports in the same bundle
■
Any combination of bundles that does not exceed the 336 available T1
channels (for example, 336 single-link T1 bundles, 42 eight-link bundles, or
41 eight-link bundles and 8 single-link bundles)
■
On an ES2-S1 Service IOA, you can configure:
■
Up to 16,000 member links per line module, not to exceed a total of 12,000
MLPPP bundles per chassis
■
Any combination of bundles that does not exceed either of these maximums
(for example, 4000 single-link bundles, 4000 two-link bundles, 4000 four-link
bundles, and 2000 eight-link bundles)
■
On an OCx/STMx ATM line module and its corresponding line modules, you can
configure:
■
Up to 8000 member links per line module, not to exceed a total of 8000
MLPPP bundles per chassis
■
Any combination of bundles that does not exceed either of these maximums
(for example, 4000 single-link bundles, 4000 two-link bundles, 2000 four-link
bundles, and 1000 eight-link bundles)
■
On a Service line module (SM), you can configure:
■
Up to 16,000 member links per line module, not to exceed a total of 12,000
MLPPP bundles per chassis
■
Any combination of bundles that does not exceed either of these maximums
(for example, 4000 single-link bundles, 4000 two-link bundles, 4000 four-link
bundles, and 2000 eight-link bundles)
■
On a shared tunnel-server port configured on a GE-2 or GE-HDE line module and
corresponding line modules, you can configure:
■
Up to 8000 member links per line module, not to exceed a total of 8000
MLPPP bundles per chassis
■
Any combination of bundles that does not exceed either of these maximums
(for example, 4000 single-link bundles, 4000 two-link bundles, 2000 four-link
bundles, and 1000 eight-link bundles)
■
On an ES2-S1 GE-4 IOA, ES2-S1 GE-8 IOA, ES2-S1 OC3-8 STM1 ATM IOA, and
ES2-S1 OC12-2 STM4 ATM IOA modules that pair with an ES2 4G LM on E120
and E320 routers, you can configure:
310
■
Supported MLPPP Features
JUNOSe 11.1.x Link Layer Configuration Guide
Содержание JUNOSE 11.1.X - LINK LAYER CONFIGURATION 4-7-2010
Страница 6: ...vi...
Страница 8: ...viii JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 26: ...xxvi List of Figures JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 34: ...2 Chapters JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 200: ...168 Monitoring Upper Level Protocols over Ethernet JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 230: ...198 Monitoring VLAN and S VLAN Subinterfaces JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 258: ...226 Monitoring 802 3ad Link Aggregation JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 334: ...302 Troubleshooting JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 394: ...362 Monitoring Multiclass MLPPP JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 406: ...374 Monitoring POS JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 468: ...436 Troubleshooting JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 498: ...466 Monitoring Bridged Ethernet JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 546: ...514 Monitoring Cisco HDLC JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 747: ...Part 2 Index Index on page 717 Index 715...
Страница 748: ...716 Index JUNOSe 11 1 x Link Layer Configuration Guide...
Страница 774: ...742 Index JUNOSe 11 1 x Link Layer Configuration Guide...