215
F3
Last Trip C-N (C-A) RMS Voltage
Class 1
96
216
F3
Last Trip System Frequency
Class 1
97
217
F1
Last Trip Analog Input
Class 1
98
218
F1
Last Trip Neutral Current
Class 1
99
219
F23
Date Of Fault 1 (Upper 16 Bits - See Note 1)
Class 3
Note 1
100
220
F23
Date Of Fault 1 (Lower 16 Bits - See Note 1)
Class 3
Note 1
101
221
F22
Time Of Fault 1 (Upper 16 Bits - See Note 1)
Class 3
Note 1
102
222
F22
Time Of Fault 1 (Lower 16 Bits - See Note 1)
Class 3
Note 1
103
223
F76
Type Of Fault 1
Class 3
104
224
F52
Distance To Fault 1
Class 3
105
225
F53
Line Z1 To Fault 1 (Magnitude)
Class 3
106
226
F23
Date Of Fault 2 (Upper 16 Bits - See Note 1)
Note 1
107
227
F23
Date Of Fault 2 (Lower 16 Bits - See Note 1)
Note 1
108
228
F22
Time Of Fault 2 (Upper 16 Bits - See Note 1)
Note 1
109
229
F22
Time Of Fault 2 (Lower 16 Bits - See Note 1)
Note 1
110
230
F76
Type Of Fault 2
111
231
F52
Distance To Fault 2
112
232
F53
Line Z1 To Fault 2 (Magnitude)
113
233
F23
Date Of Fault 3 (Upper 16 Bits - See Note 1)
Note 1
114
234
F23
Date Of Fault 3 (Lower 16 Bits - See Note 1)
Note 1
115
235
F22
Time Of Fault 3 (Upper 16 Bits - See Note 1)
Note 1
116
236
F22
Time Of Fault 3 (Lower 16 Bits - See Note 1)
Note 1
117
237
F76
Type Of Fault 3
118
238
F52
Distance To Fault 3
119
239
F53
Line Z1 To Fault 3 (Magnitude)
120
240
F23
Date Of Fault 4 (Upper 16 Bits - See Note 1)
Note 1
121
241
F23
Date Of Fault 4 (Lower 16 Bits - See Note 1)
Note 1
122
242
F22
Time Of Fault 4 (Upper 16 Bits - See Note 1)
Note 1
123
243
F22
Time Of Fault 4 (Lower 16 Bits - See Note 1)
Note 1
124
244
F76
Type Of Fault 4
125
245
F52
Distance To Fault 4
126
246
F53
Line Z1 To Fault 4 (Magnitude)
127
247
F23
Date Of Fault 5 (Upper 16 Bits - See Note 1)
Note 1
128
248
F23
Date Of Fault 5 (Lower 16 Bits - See Note 1)
Note 1
129
249
F22
Time Of Fault 5 (Upper 16 Bits - See Note 1)
Note 1
POINT LIST FOR:
ANALOG INPUT (OBJECT 30)
ANALOG INPUT CHANGE (OBJECT 32)
(Continued)
(Note 5) Index when
Point Mapping Is:
Format
Description
Event
Class
Assigned
To
Notes
Disabled
Enabled
Содержание 750
Страница 2: ......
Страница 4: ......
Страница 124: ...8 14 750 760 Feeder Management Relay GE Power Management 8 12 INSTALLATION 8 S1 RELAY SETUP 8 ...
Страница 144: ...10 14 750 760 Feeder Management Relay GE Power Management 10 10 MISCELLANEOUS FUNCTIONS 10 S3 LOGIC INPUTS 10 ...
Страница 152: ...11 8 750 760 Feeder Management Relay GE Power Management 11 3 OUTPUT RELAYS 3 7 AUXILIARY 11 S4 OUTPUT RELAYS 11 ...
Страница 216: ...12 64 750 760 Feeder Management Relay GE Power Management 12 9 BREAKER FAILURE 12 S5 PROTECTION 12 ...
Страница 484: ...17 78 750 760 Feeder Management Relay GE Power Management 17 10 PLACING THE RELAY IN SERVICE 17 COMMISSIONING 17 ...
Страница 488: ...A 4 750 760 Feeder Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 490: ...B 2 750 760 Feeder Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 492: ...C 2 750 760 Feeder Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 502: ...x 750 760 Feeder Management Relay GE Power Management INDEX ...
Страница 503: ...GE Power Management 750 760 Feeder Management Relay NOTES ...