1.2 TECHNICAL SPECIFICATIONS
1 PRODUCT OVERVIEW
1
1.2.3 MEASURED PARAMETERS
(Accuracies based on less than 2 x CT and 50 to 130 V inputs)
* Full Scale = 2 x CT @ 1 x VT Full Scale x
√
3
GENERAL
The harmonic components of current and voltage are removed from the input voltage and current parameters,
so all relay measurements based on these quantities respond to the fundamental component only. To minimize
errors, the A/D process utilizes a sampling rate that is automatically adjusted to be 16 samples per power fre-
quency cycle when a measurable voltage is available. To prevent overreaching of overcurrent elements, a dig-
ital filter removes the transient DC component of currents.
CURRENT
Phase A RMS Current Phasor
Phase B RMS Current Phasor
Phase C RMS Current Phasor
% of Load-To-Trip
Accuracy:
± 0.5% of full scale
VOLTAGE
A–N (A–B) RMS Voltage Phasor
B–N (B–C) RMS Voltage Phasor
C–N (C–A) RMS Voltage Phasor
Accuracy:
± 0.25% of full scale
FREQUENCY
A-N (A-B) Bus & Line Voltage
Range:
16 to 90 Hz
Accuracy:
± 0.02 Hz
SYMMETRICAL COMPONENTS
Current Level Accuracy:± 1.5% of full scale
Voltage Level Accuracy:± 0.75% of full scale
Current & Voltage
Angle Accuracy: ± 2°
3
Φ
POWER FACTOR
Range:
0.00 Lag to 1.00 to 0.00 Lead
Accuracy:
± 0.02
3
Φ
REAL POWER
Range:
–3000.0 to 3000.0 MW
Accuracy:
± 1% of full scale
3
Φ
REACTIVE POWER
Range:
–3000.0 to 3000.0 Mvar
Accuracy:
± 1% of full scale *
3
Φ
APPARENT POWER
Range:
–3000.0 to 3000.0 MVA
Accuracy:
± 1% of full scale *
WATT-HOURS
Range:
–2.1 x 10
8
to 2.1 x 10
8
MWh
Accuracy:
± 2% of full scale * per hour
VAR-HOURS
Range:
–2.1 x 10
8
to 2.1 x 10
8
MVar
Accuracy:
± 2% of full scale * per hour
DEMAND
Phase A/B/C Current
Range:
0 to 65535 A
3
Φ
Real Power
Range:
–3000.0 to 3000.0 MW
3
Φ
Reactive Power
Range:
–3000.0 to 3000.0 Mvar
3
Φ
Apparent Power
Range:
–3000.0 to 3000.0 MVA
Measurement Type:
Thermal Exponential, 90%
response time (programmed): 5, 10,
15, 20, 30, or 60 min.
Block Interval / Rolling Demand,
time interval (programmed): 5, 10,
15, 20, 30, or 60 min.
Accuracy:
± 2% of full scale *
Содержание 750
Страница 2: ......
Страница 4: ......
Страница 124: ...8 14 750 760 Feeder Management Relay GE Power Management 8 12 INSTALLATION 8 S1 RELAY SETUP 8 ...
Страница 144: ...10 14 750 760 Feeder Management Relay GE Power Management 10 10 MISCELLANEOUS FUNCTIONS 10 S3 LOGIC INPUTS 10 ...
Страница 152: ...11 8 750 760 Feeder Management Relay GE Power Management 11 3 OUTPUT RELAYS 3 7 AUXILIARY 11 S4 OUTPUT RELAYS 11 ...
Страница 216: ...12 64 750 760 Feeder Management Relay GE Power Management 12 9 BREAKER FAILURE 12 S5 PROTECTION 12 ...
Страница 484: ...17 78 750 760 Feeder Management Relay GE Power Management 17 10 PLACING THE RELAY IN SERVICE 17 COMMISSIONING 17 ...
Страница 488: ...A 4 750 760 Feeder Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 490: ...B 2 750 760 Feeder Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 492: ...C 2 750 760 Feeder Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 502: ...x 750 760 Feeder Management Relay GE Power Management INDEX ...
Страница 503: ...GE Power Management 750 760 Feeder Management Relay NOTES ...