16.4 MODBUS MEMORY MAP
16
S5
NEGATIVE SEQUENCE DIRECTIONAL
READ/WRITE
1730
1
Negative Sequence Directional Function
---
---
F38
Disabled
1731
1
Neg Seq Directional Maximum Torque Angle (MTA)
0 to 359
°
F1
315°
1732
1
Minimum Polarizing Voltage
0.00 to 1.25
x VT
F3
0.05 x VT
1733
1
Negative Sequence Directional Relays
---
---
F57
None
S5
SENSITIVE GROUND INSTANTANEOUS OC
READ/WRITE
1740
3
S ensitive G round Instantaneous O vercurrent F unction
---
---
F37
Disabled
1741
3
Sensitive Ground Instantaneous Overcurrent Relays
---
---
F57
None
1742
3
Sensitive Ground Instantaneous Overcurrent Pickup
0.005 to 1.000
x CT
F70
0.100 x CT
1743
3
Sensitive Ground Instantaneous Overcurrent Delay
0.00 to 600.00
s
F3
0.00 s
1744
3
S ensitive G round Instantaneous O vercurrent D irection
---
---
F84
Disabled
S5
SENSITIVE GROUND TIME OC
READ/WRITE
1750
3
Sensitive Ground Time Overcurrent Function
---
---
F37
Disabled
1751
3
Sensitive Ground Time Overcurrent Relays
---
---
F57
None
1752
3
Sensitive Ground Time Overcurrent Curve
---
---
F36
Ext. Inverse
1753
3
Sensitive Ground Time Overcurrent Pickup
0.005 to 1.000
x CT
F70
0.100 x CT
1754
3
Sensitive Ground Time Overcurrent Multiplier
0.00 to 100.00
---
F3
1.00
1755
3
Sensitive Ground Time Overcurrent Reset Time
---
---
F68
Instantaneous
1756
3
Sensitive Ground Time Overcurrent Direction
---
---
F84
Disabled
S5
SENSITIVE GROUND DIRECTIONAL
READ/WRITE
1760
3
Sensitive Ground Directional Function
---
---
F38
Disabled
1761
3
S ensitive G round D irectional M axim um Torque A ngle
0 to 359
°
F1
315°
1762
3
Minimum Polarizing Voltage
0.00 to 1.25
x VT
F3
0.05 x VT
1763
3
Sensitive Ground Directional Polarizing
---
---
F50
Voltage
1764
3
Sensitive Ground Directional Relays
---
---
F57
None
S5
7
RESERVED FOR MOD 010
READ/WRITE
1767
7
Reserved for MOD 010
1768
7
Reserved for MOD 010
1769
7
Reserved for MOD 010
176A
7
Reserved for MOD 010
176B
7
Reserved for MOD 010
S5
RESTRICTED EARTH FAULT (REF)
READ/WRITE
1770
8
Restricted Earth Fault Function
---
---
F39
Disabled
Table 16–15: MODBUS MEMORY MAP (Sheet 26 of 41)
ADDR
DESCRIPTION
RANGE
UNITS
TYPE
FACTORY
DEFAULT
1 2 3 4 5 6 7 8 9
For explanation of Table footnotes, see page 16–59.
Содержание 750
Страница 2: ......
Страница 4: ......
Страница 124: ...8 14 750 760 Feeder Management Relay GE Power Management 8 12 INSTALLATION 8 S1 RELAY SETUP 8 ...
Страница 144: ...10 14 750 760 Feeder Management Relay GE Power Management 10 10 MISCELLANEOUS FUNCTIONS 10 S3 LOGIC INPUTS 10 ...
Страница 152: ...11 8 750 760 Feeder Management Relay GE Power Management 11 3 OUTPUT RELAYS 3 7 AUXILIARY 11 S4 OUTPUT RELAYS 11 ...
Страница 216: ...12 64 750 760 Feeder Management Relay GE Power Management 12 9 BREAKER FAILURE 12 S5 PROTECTION 12 ...
Страница 484: ...17 78 750 760 Feeder Management Relay GE Power Management 17 10 PLACING THE RELAY IN SERVICE 17 COMMISSIONING 17 ...
Страница 488: ...A 4 750 760 Feeder Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 490: ...B 2 750 760 Feeder Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 492: ...C 2 750 760 Feeder Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 502: ...x 750 760 Feeder Management Relay GE Power Management INDEX ...
Страница 503: ...GE Power Management 750 760 Feeder Management Relay NOTES ...