GE Power Management
750/760 Feeder Management Relay
16-
85
16 COMMUNICATIONS
16.5 DNP 3.0 DEVICE PROFILE
16
1.
The data link layer confirmation mode, confirmation timeout and number of retries are all configurable. Refer to the set-
points defined under
S1 RELAY SETUP / COMMUNICATIONS / DNP
for more details. Additional setpoints related to DNP
are discussed in Section 8.3: DNP COMMUNICATIONS on page 8–3.
Executes Control Operations:
WRITE Binary Outputs
Never
p
Always
p
Sometimes
p
Configurable
SELECT/OPERATE
p
Never
Always
p
Sometimes
p
Configurable
DIRECT OPERATE
p
Never
Always
p
Sometimes
p
Configurable
DIRECT OPERATE - NO ACK
p
Never
Always
p
Sometimes
p
Configurable
Count > 1
Never
p
Always
p
Sometimes
p
Configurable
Pulse On
p
Never
p
Always
Sometimes
p
Configurable
Pulse Off
Never
p
Always
p
Sometimes
p
Configurable
Latch On
p
Never
p
Always
Sometimes
p
Configurable
Latch Off
p
Never
p
Always
Sometimes
p
Configurable
Trip/Close
p
Never
p
Always
Sometimes
p
Configurable
(For an explanation of the above, refer to the discussion accompanying the point list for the Binary Output/
Control Relay Output Block objects)
Queue
Never
p
Always
p
Sometimes
p
Configurable
Clear Queue
Never
p
Always
p
Sometimes
p
Configurable
Reports Binary Input Change Events when no
specific variations requested:
p
Never
Only time-tagged
p
Only non-time-tagged
p
Configurable to send both, one or the other
Reports time-tagged Binary Input Change Events
when no specific variation requested:
p
Never
Binary Input Change With Time
p
Binary Input Change With Relative Time
p
Configurable
Sends Unsolicited Responses:
Never
p
Configurable
p
Only certain objects
p
Sometimes
p
ENABLE/DISABLE UNSOLICITED
Function codes supported
Sends Static Data in Unsolicited Responses:
Never
p
When Device Restarts
p
When Status Flags Change
Default Counter Object/Variation:
No Counters Reported
p
Configurable
p
Default Object
Default Variation
p
Point-by-point list attached
Counters Roll Over at:
No Counters Reported
p
Configurable
p
16 Bits
p
32 Bits
p
Other Value
p
Point-by-point list attached
Sends Multi-Fragment Responses:
p
Yes
No
DNP 3.0
DEVICE PROFILE DOCUMENT (Continued)
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Содержание 750
Страница 2: ......
Страница 4: ......
Страница 124: ...8 14 750 760 Feeder Management Relay GE Power Management 8 12 INSTALLATION 8 S1 RELAY SETUP 8 ...
Страница 144: ...10 14 750 760 Feeder Management Relay GE Power Management 10 10 MISCELLANEOUS FUNCTIONS 10 S3 LOGIC INPUTS 10 ...
Страница 152: ...11 8 750 760 Feeder Management Relay GE Power Management 11 3 OUTPUT RELAYS 3 7 AUXILIARY 11 S4 OUTPUT RELAYS 11 ...
Страница 216: ...12 64 750 760 Feeder Management Relay GE Power Management 12 9 BREAKER FAILURE 12 S5 PROTECTION 12 ...
Страница 484: ...17 78 750 760 Feeder Management Relay GE Power Management 17 10 PLACING THE RELAY IN SERVICE 17 COMMISSIONING 17 ...
Страница 488: ...A 4 750 760 Feeder Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 490: ...B 2 750 760 Feeder Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 492: ...C 2 750 760 Feeder Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 502: ...x 750 760 Feeder Management Relay GE Power Management INDEX ...
Страница 503: ...GE Power Management 750 760 Feeder Management Relay NOTES ...