1.1 INTRODUCTION
1 PRODUCT OVERVIEW
1
1.1.2 SUMMARY OF FEATURES
PROTECTION
•
Two Phase Time Overcurrent Elements with Voltage
Restraint
•
Two Phase Instantaneous Overcurrent Elements
•
Two Neutral Time Overcurrent Elements
•
Two Neutral Instantaneous Overcurrent Elements
•
Ground Time and Instantaneous Overcurrent
•
Sensitive Ground Time and Instantaneous Overcur-
rent
•
Negative Sequence Time and Instantaneous Overcur-
rent
•
Phase, Neutral, Ground, Sensitive Ground, and Nega-
tive Sequence Directional Control
•
Negative Sequence Voltage
•
Neutral Displacement
•
Two Bus Undervoltage Elements
•
Two Line Undervoltage Elements
•
Two Overvoltage Elements
•
Two Underfrequency Elements
•
Frequency Decay
•
Breaker Failure with Current Supervision
INPUTS
•
5 - AC Currents
•
4 - AC Voltages
•
20 Programmable Logic Inputs
(14 contact and / or virtual)
(6 virtual)
•
1 Analog Input
OUTPUTS
•
8 Electro-Mechanical Relays
•
1 Solid-State Trip
•
8 Analog Transducers
MONITORING
•
Phase and Neutral Current Level
•
Power Factor
(Two Independent Stages)
•
Fault Locator
•
Demand
(I
a
, I
b
, I
c
, MW, Mvar, MVA)
•
Analog Input
(Two Threshold Stages)
(Two Rate Stages)
•
Overfrequency
•
Trip Counter Limit
•
Total Breaker Arcing Current
(Per Phase)
•
Breaker Operation Failure
•
Trip and Close Coil Monitors
•
VT Failure
•
Pulsed Output
METERING
•
Average Current
•
Phase, Neutral, Ground, and Sensitive Ground Cur-
rent Phasors
•
Average Line and Phase Voltage
•
Line and Phase Voltage Phasors
•
Symmetrical Component Phasors
(Current and Voltage)
•
Frequency Magnitude and Rate
•
Synchronizing Voltage Phasor
•
Synchronizing Voltage Frequency
•
Synchronizing
∆Φ
,
∆
kV,
∆
Hz
•
Single and Three Phase Power
(MW, Mvar, MVA, PF)
•
Energy
(MWh, Mvarh)
•
Last and Maximum Demand
(I
a
, I
b
, I
c
, MW, Mvar, MVA)
•
Analog Input Magnitude
•
Analog Input Rate
(per minute, per hour)
Содержание 750
Страница 2: ......
Страница 4: ......
Страница 124: ...8 14 750 760 Feeder Management Relay GE Power Management 8 12 INSTALLATION 8 S1 RELAY SETUP 8 ...
Страница 144: ...10 14 750 760 Feeder Management Relay GE Power Management 10 10 MISCELLANEOUS FUNCTIONS 10 S3 LOGIC INPUTS 10 ...
Страница 152: ...11 8 750 760 Feeder Management Relay GE Power Management 11 3 OUTPUT RELAYS 3 7 AUXILIARY 11 S4 OUTPUT RELAYS 11 ...
Страница 216: ...12 64 750 760 Feeder Management Relay GE Power Management 12 9 BREAKER FAILURE 12 S5 PROTECTION 12 ...
Страница 484: ...17 78 750 760 Feeder Management Relay GE Power Management 17 10 PLACING THE RELAY IN SERVICE 17 COMMISSIONING 17 ...
Страница 488: ...A 4 750 760 Feeder Management Relay GE Power Management A 1 FIGURES AND TABLES APPENDIXA A ...
Страница 490: ...B 2 750 760 Feeder Management Relay GE Power Management B 1 EU DECLARATION OF CONFORMITY APPENDIXB B ...
Страница 492: ...C 2 750 760 Feeder Management Relay GE Power Management C 1 WARRANTY INFORMATION APPENDIXC C ...
Страница 502: ...x 750 760 Feeder Management Relay GE Power Management INDEX ...
Страница 503: ...GE Power Management 750 760 Feeder Management Relay NOTES ...