Unit Bay Status Type FanStatus FanSpeed(rpm) Power Usage
(W)
--------------------------------------------------------------
0 0 down AC up 1376 0.0
0 1 up AC up 18848 666.0
0 2 down AC up 1312 0.0
0 3 up AC up 18880 643.0
Dell#show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------
0 0 up up 5263 up 5292
0 1 up up 5274 up 5317
0 2 up up 5256 up 5292
0 3 up up 5278 up 5328
0 4 up up 5270 up 5320
Speed in RPM
Dell#show environment thermal-sensors
-- Thermal Sensor Readings (deg C) --
Module S0 S1 S2 S3 S4 S5
S6 S7 S8 S9 S10
---------------------------------------------------------------
------------------------------------
System Core 33 33 34 33 28 39
25 36 39 39 -
Switching Core 100[M] 46 47 45 44 45
- - - - -
Port Modules 49 101[M] 60 49 62 52
78 55 53 50 46
Threshold crossed [m]: minor [M]: major, [S]: shutdown
show inventory
Display the switch type, components (including media), and Dell Networking OS version, including
hardware identification numbers and configured protocols.
Z9500
Syntax
show inventory [media
slot-id
]
Parameters
media
slot-id
(OPTIONAL) Enter the keyword
media
to display pluggable
media inventory for a specified line-card slot. Valid slot ID
are from 0 to 2.
Defaults
none
Control and Monitoring
147
Содержание Networking Z9500
Страница 1: ...Dell Networking Command Line Reference Guide for the Z9500 Switch 9 8 0 0 ...
Страница 344: ...Version Description 9 8 0 0 Introduced on the S6000 Z9500 344 Access Control Lists ACL ...
Страница 738: ...Invalid File 0 Invalid Binding Entry 0 Binding Entry lease expired 0 Dell 738 Dynamic Host Configuration Protocol DHCP ...
Страница 1704: ...Samples rcvd from h w 0 Total UDP packets exported 0 UDP packets exported via RPM 0 UDP packets dropped 0 Dell 1704 sFlow ...
Страница 1881: ... Po 55 00 01 e8 8a e8 f7 3 7 8 Macs learnt via port channel 55 Po 55 00 01 e8 8b 1c c0 3 7 8 VLT Proxy Gateway 1881 ...